Pune
08048128313
+919822062991

Products

68179d65be22ee500d53ff54 Card 2

product image
Implant

Safe & excellent surgical procedure Patent Application •The shield cover with a 360 – degree revolution can approach in the oral cavity freely •The shield cover rotates to fit on the surface of the bone. It enables you to do the safe surgical procedure. •The hole on the shield cover can make a dentist to observe the surgical area easily. •Holes for lessening bone heating. •Saw thickness : 0.35mm including diamond coating layer. •No shaking and superior cutting power. •Possible to change direction gradually during bone cutting. •Automatic fixation for 0.5~2.5mm. •The shank fixation distance of a handpiece is different according to the brand •Special materials are used. - Excellent corrosion resistance and thermal resistance. - Low noise and improved rotatory power. **It can be combined with various handpieces such as KaVo, W&H, NSK, etc.**

68179d65be22ee500d53ff54 Card 2

product image
Implant

Micro saw is a rotary cutting instrument for removing unnecessary bone torus or extremely thin ridge crest. Also it can be used for ridge split or block bone surgery. Contra Angle Use a contra angle handpiece for cutting bone in widthwise direction. >MICSA08 8mmDia. >MICSA10 10mmDia >MICSA13 13mmDia >MICSA15 15mmDia Straight Angle Use a straight handpiece for cutting bone in lengthwise direction in supplement for wider expanding. >MICSS08 8mmDia >MICSS10 10mmDia >MICSS13 13mmDia >MICSS15 15mmDia Advantages compared to competitors •Holes for lessening bone heating. •Saw thickness : 0.35mm including diamond coating layer. •No shaking and superior cutting power. •The vibration is minimized during bone cutting because of the diamond coating surface. •Possible to change direction gradually during bone cutting.

68179d65be22ee500d53ff54 Card 2

product image
Implant

Trephine Bur •3.0/2.0mm trephine bur (THB30) can be used as an initial drill harvesting bone. •Make a path with reverse rotation and use a normal rotation at 800-1,200rpm •Used for the harvesting of mandibular bone. •Choose a proper size of trephine bur for failed fixture removing. For Bone Harvesting Product Code Internal Diameter External Diameter THB30 2mm 3mm THB40 3mm 4mm THB50 4mm 5mm THB60 5mm 6mm THB70 6mm 7mm THB80 7mm 8mm THB90 8mm 9mm To Remove Implant Product Code Internal Diameter External Diameter THR50 4mm 5mm THR60 5mm 6mm

68179d65be22ee500d53ff54 Card 2

product image
Implant

A Concave Osteotome is used for the sinus elevation surgery. It can be used when the alveolar bone is very thin up to 1~2mm. The floor of the sinus is then lifted by tapping the sinus floor with the use of Osteotomes. BOCV20F 2.0mm BOCV28F 2.8mm BOCV33F 3.3mm BOCV36F 3.6mm BOCV43F 4.3mm BOCV50F 5.5mm

68179d65be22ee500d53ff54 Card 2

product image
Implant

A convex Osteotome is used for the stable initial fixation of an implant through condensing alveolar bone laterally. It has a stopper for safe Osteotome technique. BOVX28F 2.8mm BOVX33F 3.3mm BOVX38F 3.8mm BOVX43F 4.3mm BOVX50F 5.0mm

68179d65be22ee500d53ff54 Card 2

product image
Implant

Bone Scraper BSF •Sterilized product. Single-use. •Size 148 x 17 x 16H(mm) •If the blade becomes dull, rotate the blade with any 1.2mm hex driver to expose a new sharp edge. •5 pcs **The bone scraper comes packed as sterile products. It is very convenient to use.** Block Bone Clamp RCA197 •Anterior •Used for holding block bone •The length is 197mm RCP200 •Posterior •Used for holding block bone •The length is 200mm •Drilling available through the slot of the beak

68179d65be22ee500d53ff54 Card 2

product image
Implant

Bone Collect Chisel STSBC-1 •Used for collecting osseous coagulum, Back-action Bone Collector ST1 •Used for collecting bone particles cut off while drilling. •To take osseous coagulum inhaled by suction using a filter. •Length 235mm •The filter is single-use. ST1-F Bone Collector Filter •Disposable Hexa Wrench 5mm IDH5-15N 15N Toque Wrench •Alert not to give excess power as it is bent if power is over 15N IDH7-15N 7mm 15N Toque Wrench •Alert not to give excess power as it is bent if power is over 15N

68179d65be22ee500d53ff54 Card 2

product image
Implant

Bone Crusher •The punching head has a round shape to effectively crush bone with a relatively small force. And the punching tool doesn’t get jammed to the bowl due to its rounded shape. Bone Crusher Mallet ML29 •Durable and strong stainless steel mallet. Suitable for bone crushing procedure.

68179d65be22ee500d53ff54 Card 2

product image
Implant

Bone Mill BMH •Hinge type •Serrated disks are made of titanium. •Place a small bock bone between two serrated disks for grinding so the particles are minutely broken. •Easy & simple to use. Bone Syringe •Placing graft material into recipient site / stainless steel made •To carry grained bone into the recipient site BSY35 •For the socket approach •Useful for fine & high-flowable bone particles. •Inner Diameter 2.5mm / Outer Diameter 3.5mm BSY47 •Most popular size. •Inner Diameter 3.7mm / Outer Diameter 4.7mm BSY70 •Used for lateral approach. It is able to carry large volume of material. •Inner Diameter 6.0mm / Outer Diameter 7.0mm

68179d65be22ee500d53ff54 Card 2

product image
Implant

Bone Carrier BSC3539 •To carry bone graft material •Titanium made Bone Packer GP2530 GP3340 Bone Well BWSUS1 •Used for mixing bone graft material •Made of stainless steel •Size : Diameter 38 x 27.5H(mm)

68179d65be22ee500d53ff54 Card 2

product image
Implant

RNGSK100 •Kerrison •To open sinus window •Length of beak 10cm •Width of bite 4mm

68179d65be22ee500d53ff54 Card 2

product image
Implant

OCAKIT •Everyone gets the same result in operation as the drill stops by itself when it touches the sinus membrane. •Riskless in the matter of membrane-tear as the membrane is lifted by using hydraulic pressure. 1) Pilot Drill ø1.8 •To mark a position of an implant after confirmation of X-ray 2)Stopper (2mm ~ 10mm) •Control depth 3) A.I. Drill •Drill stops automatically when the drill touches sinus membrane (by 1,200rpm) 4) Cannon Drill ø2.4 •Initial drill to access the sinus before the use of A.I. drill. 5) Cannon Drill ø3.2 •Used for expanding a hole size. •Can be used with a stopper. 6) Aqua tap •Used for injecting a saline solution or contrast medium into the perforated maxillary sinus. 3.15S 3.15 3.5 Diameter Ø3.15 Ø3.15 Ø3.5 Length 28mm 33mm 33mm 7)Hand Adapter 8)Engine Adapter •Adapter for connecting Aquatap to the implant handpiece. 9)Hand Wrench 10) Sensor Gauge •To check perforation of the sinus membrane by using compression of spring 11) Bone Condensor •Condensing bone material into the maxillary sinus 12) Bone Carrier •Carry bone material to the maxillary sinus

Phone Number

08048128313

Please keep 0 before dialling the number.

Email Address dent.techno@gmail.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Office no 1, Suvidha Corner, Sheela Vihar Colony, 298 Erandavane, Karve Road, Pune.(Maharashtra) 411038

Pune, India, 411038